High Pressure Steam Sterilizer Mac
Robus Autoclave |
Robus Autoclave |
Robus Autoclave |
RTA60 | RTA85 | RTA110 |
Saving The Installation Space
The main body is very compact owing to the design which provides through installation space saving. In addition, installation space at the side of the main body is required for models employing a slide-open lid, which is not necessary at ROBUS autoclaves’ top-open lid. Even when several Robus autoclaves are installed side-by-side, the necessary installation space is minimized.
Product Description
- Fully stainless steel 304 structure.
- Wing nut locking mechanism.
- Microprocessor control, digital display of working status: pressure, time, temperature, error code, touch type key.
- Auto discharge the cool air, and steam discharges automatically after sterilization.
- Self-inflating type seal.
- Automatically shut off with a beep reminder after sterilization.
- A Standard PT/TT test interface is provided for convenient testing.
- With two stainless steel sterilization.
- Equipped with an automatic water sensor and water level indicator.
- Equipped with a lid protection cover.
Safety Protection Device
- Safe protection of water lacking
- The program will be stopped if the water level is lower than the low limit.
- Over temperature& over pressure auto-protection.
- Over-current protector.
- Door safety interlock system.
- The safety valve of auto release against over-pressure.
Technical Specifications
Model | |||
RTA60 | RTA85 | RTA110 | |
Capacity(L) | 60 | 85 | 110 |
Sterilization mode | Solid mode: Heating-Sterilizing-Exhausting and air cooling |
||
Liquid mode: Heating-sterilizing-Precooling-Steam exhausting |
|||
Waste Mode: Heating-Sterilizing-Steam exhausting and air cooling |
|||
Agar Mode: Heating-Melting-Warming |
|||
Chamber material | SUS304 | ||
Rated power supply | 220V/50Hz | ||
Rated power(W) | 2900 | 4600 | 4600 |
Sterilization temperature | 105—138℃ | ||
Range of sterilization time | 1—300minutes | ||
Melting temperature | 60—100℃ | ||
Range of melting time | 1—300minutes | ||
Warming temperature | 45—60℃ | ||
Range of melting time | 1—9999minutes | ||
Preset range of cooling lock OPEN temperature | 40-99℃ for solid and agar modes and 40-80℃ for liquid and waste modes | ||
Preset range of steam exhausting temperature | 73—104℃ | ||
Exhausting mode | Fully automatic internal discharging Embedded with a steam trapping bottle |
||
Way of opening lid | Flip type | ||
Preset range of timer | 0 minute-6 days delayed | ||
Preset range of timer | 0-0.6MPa | ||
The preset temperature of chamber lid opening | presentable | ||
Rated working pressure | 0.27 MPa | ||
Controller | “Inspiration” fast-speed microcomputer intelligent control system | ||
Safety device | “eight-column evenly distributed” interlocking device, electric double inner locks, dry scorch protection, overpressure protection, safety valve, over temperature protection, over current and short circuit protection, leakage protection, cooling lock, anti-scald chamber cove rand bench, automatic troubleshooting | ||
Accessories | drainage hose, water plate, exhaust bottle | ||
Two stainless steel baskets | Two stainless steel baskets | Three stainless steel baskets |